Impulse Current Generator

Customization:
Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Product Description

- Impulse current generator 120kA 8/20us, suitable for test surge protection products, metal oxide varistors (MOV), gas discharge tubes (GDT).
- Generator design has large current margin, the charge and discharge hundreds of thousands of times in life.
- AC constant current source charging, transformer bridge rectifier, the capacitor voltage linearly increased, and impact on the capacitor are small, and reduce the power consumption of the device.
- Using cylinder discharge, discharge of high-density graphite ball processing, discharge, reliable, maintenance-free, anti-erosion discharge the ball.
- Controlled by PLC, operator interface with 7-inch color touch screen, the touch screen to set the discharge voltage, discharge frequency, time interval, and can touch the screen to perform manual operation and automatic operation, bar graph displays the remaining time, and control is more advanced.

The impulse current generator is combined from high voltage main circuit, the test product cabinet, control cabinet and so on. Charging part is adopting AC constant current source. AC adapter output through the bridge rectifier to the capacitor after the charge. Off the power or press the "emergency stop" button, all the high-voltage power transformers and capacitors by ground water resistance grounded cylinder. Capacitor discharge and transfer back to the routing wave resistance, inductance modulation wave form. The impact of using Rogowski coil current sensor, voltage divider with residual pressure of Taiwan 1000: 1 high voltage probe, pulse voltage, current through the two-channel digital storage oscilloscope Tektronix displayed simultaneously.

The control is achieved by OMRON PLC, operator interface with 7-inch color LCD touch screen. The touch screen is set the discharge voltage, discharge frequency, time interval and so on.

Testing Lab. Requirement:
Power supply: Single phase, 240V/5kVA
Air pressure: 0.4MPa, 0.1m3/min
Grounding: Grounding independently, grounding resistance 1Ω
Current Waveform 8/20us Tolerance
Front time 8us ± 10%
Time to half value 20us ± 10%
Reverse current peak < 20%
Range of maximum discharge current                                                                             10kA~120kA
Range of residual voltage                                                                                 0~6000V
Impulse lifetime Impulse lifetime of 120kA several hundred thousandtimes
Standard IEC-61643 and UL1449

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2013

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
20
Year of Establishment
2019-02-18